Introducing our latest product, The V-Series Electric Boiler, bringing everything our customers have come to expect in high-performance steam generation, all without the need for fossil fuel connections or exhaust stacks. Powered by advanced stainless steel heating elements and Clayton’s unique forced circulation technology, the V-Series ensures reliable and efficient steam production with minimal maintenance. Thanks to its modular design, this system can be easily extended or combined with hybrid systems and heat pumps to meet the evolving needs of your operation.
The V-Series brings all of the design aspects that our customers have come to rely on, now in an electric boiler. With a quick start-up time, averaging less than five minutes from a cold start, the V-Series provides a near instant supply of high-quality steam, perfect for reducing downtime and boosting efficiency. Its compact, plug-and-play configuration makes it ideal for operations with limited space, while its fully modulating performance helps you save energy without sacrificing reliability. Designed with safety in mind, the V-Series offers a controlled, closed system equipped with advanced safety mechanisms, providing peace of mind without sacrificing performance.
As an emission-free solution, the V-Series contributes to a cleaner environment and a more sustainable future. The absence of fossil fuels and the system’s energy efficiency significantly reduces your carbon footprint, while further lowering your overall operating costs. Built for reliability and long life, Clayton’s electric steam boilers provide consistent performance and reduce your maintenance needs, keeping your facility up and running and minimizing shutdowns.
In a world where efficiency and sustainability are increasingly important, the V-Series Electric Steam Boilers offer a smarter, greener solution. Whether you’re upgrading your equipment or launching a new operation, Clayton’s latest innovation is the high-performance choice for industrial excellence.
Contact us today for more information!
Introducing the V-Series Electric Steam Boiler
15 - 45 BHP Steam Master
Our latest product, the Clayton Steam Master, is our most compact configuration yet. Available in 15, 30, and 45 Boiler Horsepower, the Steam Master is an ideal choice for any industry in need of steady, reliable steam.
Designed specifically with saving space in mind, the Clayton Steam Master provides all the efficiency, reliability, and safety you’ve come to expect from a Clayton Steam Generator, but in a smaller packaged ideal for when floorspace is a premium. With our smaller size, ease of installation, and user friendly set up, you can save on your next installation.
Despite its smaller size, the Steam Master still comes equipped with all of the features that made Clayton a leader in boiler technology, including our high efficiency, inherent safety, and precision temperature control. In an industry where power is often associated with size, our latest product proves that saving space doesn’t mean you should sacrifice reliability.
In addition, all Clayton Steam Master’s now come equipped with our environmentally friendly Low NOx configuration, reducing emissions below ten parts per million, at no additional cost, as part of our ongoing commitment towards environmentally friendly technology.
In a market where size often dictates power, our safe portable steam units break the mold. Whether you’re starting a new operation or looking to upgrade your current equipment, consider the latest product from Clayton Industries. It’s the compact, easy-to-use, and efficient solution you’ve been looking for. Contact us today for more helpful information.
Key Benefits
The Clayton Advantage
Everything you’ve come to expect from the Clayton design, including our forced circulation waterflow, quick start times, and reliable steam production, which we’ve packed into our latest product, the V-Series Electric Boiler.
Industry Leading Efficiency
Our electric technology is no exception when it comes to efficiency. Regardless of your fuel source, you can count on Clayton to continue delivering industry leading efficiency.
Steam Quality
Our latest innovation is no stranger to performance, continuing to deliver steam quality in excess of 99% dryness.
Emission Free Operation
Take advantage of a green solution that leads the way to a cleaner future. Clayton’s V-Series boilers are emission-free, eliminating the need for fossil connections or exhaust chimneys, all while lowering your carbon footprint and installation costs.
Configuration Options
| Model | Boiler Horsepower | Steam Flow (lb/hr) |
|---|---|---|
| V-5 | 5 | 172 |
| V-10 | 10 | 345 |
| V-15 | 15 | 517 |
| V-20 | 20 | 690 |
| V-30 | 30 | 1,035 |
| V-45 | 45 | 1,552 |
| V-60 | 60 | 2,070 |
| V-75 | 75 | 2,587 |
| V-90 | 90 | 3,105 |
| V-120 | 120 | 4,140 |
| V-150 | 150 | 5,175 |
Efficient, Compact, and Emission-Free
With 24/7 availability and extensive coverage throughout the United States and beyond, our skilled professionals are equipped to keep your steam generator operating at peak performance.
Looking for replacement parts? Clayton has you covered. Between our parts warehouses, manufacturing plants, and service centers located across the globe, Clayton can ensure a quick response to your steam generator needs.
Are you looking for a temporary solution? Or has a shutdown forced you into an emergency situation? Regardless of your situation, Clayton offers a range of rental solutions that will keep you up and running, complete with all of the auxiliary systems required to bring your facility back online.
In addition to our production facilities around the world, Clayton also offers a refurbishment program, providing a quality source of rebuilt units available for sale.
Why wait for an emergency shutdown to schedule maintenance? In addition to our regular and emergency services, Clayton offers extensive Preventive Maintenance programs, tailored to your needs, to ensure your steam generator continues to perform at optimal efficiency.
Feedwater quality is absolutely critical to boiler operation. Keep your system running smoothly with support from Clayton’s Chemical Water Treatment division, which allows you to take full advantage of your steam generation system.
Configuration Options
The Clayton Steam Master is available in 15. 30, and 45 Boiler Horsepower
In addition, Clayton offers packaged boiler systems configured to your specific needs, including additional options for feedwater tanks, water treatment packages, and more.
With 24/7 availability and extensive coverage throughout the United States and beyond, our skilled professionals are equipped to keep your steam generator operating at peak performance.
Looking for replacement parts? Clayton has you covered. Between our parts warehouses, manufacturing plants, and service centers located across the globe, Clayton can ensure a quick response to your steam generator needs.
Are you looking for a temporary solution? Or has a shutdown forced you into an emergency situation? Regardless of your situation, Clayton offers a range of rental solutions that will keep you up and running, complete with all of the auxiliary systems required to bring your facility back online.
In addition to our production facilities around the world, Clayton also offers a refurbishment program, providing a quality source of rebuilt units available for sale.
Why wait for an emergency shutdown to schedule maintenance? In addition to our regular and emergency services, Clayton offers extensive Preventive Maintenance programs, tailored to your needs, to ensure your steam generator continues to perform at optimal efficiency.
Feedwater quality is absolutely critical to boiler operation. Keep your system running smoothly with support from Clayton’s Chemical Water Treatment division, which allows you to take full advantage of your steam generation system.
Contact a Clayton Representative

sales@claytonindustries.com

800 423 4585 or +1 626 435 1200 PST
Frequently Asked Question's
Clayton’s V-Series uses stainless steel electrical heating elements and forced water circulation to generate steam. Electrical controls adjust heating output as demand changes. This allows the boiler to supply process steam without burning natural gas, propane, or fuel oil.
Clayton’s U.S. product page lists V-Series models from 5 to 150 BHP, with published steam capacities from 172 to 5,175 lb/hr. Examples include the V-30 at 1,035 lb/hr and the V-60 at 2,070 lb/hr. Confirm available output at your required pressure and feedwater conditions.
Clayton states that the V-Series averages less than five minutes from a cold start. Actual startup performance should be confirmed for the selected model and operating conditions. Rapid startup can support facilities that need steam for scheduled shifts or intermittent production.
No. The V-Series generates heat electrically, so it does not require a fossil fuel connection or combustion exhaust stack. Installation still requires suitable electrical service, feedwater connections, steam piping, and the supporting equipment specified for the application.
Not necessarily. Compare electricity and gas prices, boiler efficiency, operating hours, and maintenance costs for the same steam demand. Electricity tariffs may include demand charges and time-dependent rates, so a comparison based only on the price per kilowatt-hour can overlook significant costs.
Clayton’s European V-Series information lists a design efficiency of 99.6%. Confirm the applicable rating and measurement conditions for the U.S. model being quoted. Boiler efficiency should also be distinguished from overall system efficiency, which includes losses in steam distribution and other supporting equipment.
Electric steam boilers produce no on-site combustion emissions because they do not burn fuel. Emissions associated with the electricity supply depend on how that electricity is generated. Using low-carbon electricity can therefore strengthen the emissions benefits of replacing fossil-fuel-fired steam generation.
Yes. Clayton describes its electric steam generators as modular systems that can integrate with hybrid arrangements and heat pumps. A hybrid installation can retain another energy source alongside electric steam generation. The equipment and controls should be selected around available power, steam demand, and operating priorities.
Clayton specifies steam dryness above 99% for the V-Series. This indicates a low proportion of liquid moisture in the steam. Dryness does not establish chemical purity, so applications with clean-steam or direct-product-contact requirements need a separate assessment of steam quality.
Yes. Electric heating does not remove the need to control feedwater quality. A suitable treatment program helps manage scale, corrosion, and deposits that can affect steam equipment. Select the treatment approach using a water analysis and the requirements of the specific boiler and process.
Electrical requirements depend on the selected model and regional configuration. Request the U.S. specification showing voltage, phase, frequency, total connected load, and full-load current. Check these requirements against the facility’s available electrical capacity before selecting equipment; Clayton’s European voltage listings should not be assumed to apply to U.S. installations.